59G RCS-985G Generator Transformer Two stages phase to phase overvoltage protection Replay for hydro-generators, gas turbine generators and pumped-storage generators
Protection
for
Generator
Current
differential
protection.
(87G)
Unrestrained
instantaneous
differential
protection.
(87UG)
DPFC
current
differential
protection.
(87G)
High
sensitive
transverse
differential
protection.
(87G)
Longitudinal
zero
sequence
overvoltage
protection
for
turnto-
turn
fault.
(59N/60)
DPFC
directional
protection
for
turn-to-turn
fault.
(67)
Two
stages
phase-to-phase
distance
protection.
(21G)
Voltage
controlled
overcurrent
protection.
(51V)
Current
blocking
element
at
generator’s
terminal.
Fundamental
zero
sequence
overvoltage
protection
for
stator
earth
fault.
(64G1)
Third
harmonic
protection
for
stator
earth
fault.
(27/59TN,
64G2)
Two
stages
of
one-point-earth
fault
protection
of
rotor.
(64R)
Two-point
earth
fault
protection
of
rotor.
(64R)
Definite
and
inverse
time
stator
thermal
overload
protection.(49S)
Definite
and
inverse
time
negative
sequence
overload
protection
of
rotor.
(46/50,
46/51,
49R)
Loss-of-excitation
protection.
(40)
Out-of-step
protection.
(68/78)
Two
stages
phase-to-phase
overvoltage
protection.
(59G)
Phase-to-phase
undervoltage
protection.
(27G)
Two
stages
definite
time
over-excitation
protection.
(24)
Inverse
time
over-excitation
protection.
(24)
Reverse
power
protection.
(32G)
Reverse
power
protection
during
generator
shutting
down.(32G)
Three
stage
underfrequency
protection.
(81G)
Two-stage
overfrequency
protection.
(81O)
Startup/shutdown
protection
of
generator.
Accidental
energization
protection.
(50/27)
Voltage
balance
function.
(60)
Under-frequency
overcurrent
protection.
Voltage
transformer
supervision.
(47/60G)
Current
transformer
supervision.
(50/74)
Mechanical
protection.
Excitation
System
Current
differential
protection
for
exciting-transformer.
(87T)
Current
differential
protection
of
AC
exciter.
(87G)
Overcurrent
protection.
(50P/51P)
Definite
and
inverse
time
thermal
overload
protection
for
exciting
windings.
(87G)
Current
transformer
supervision
of
excitation
set.
(50/74)
Monitoring
and
Metering
Automatic
self-supervision.
Fault
recording.
Event
recording.
Present
recording.
Front
communication
port
(RS232).
Rear
communication
ports
to
host.
Rear
communication
port
to
printer.
Time
synchronization.
Voltage
and
current
drift
auto-adjustment.
The
RCS-985G
is
a
generator
protection
intended
for
the
application
to
sophisticated
generators,
including
turbogenerators,
hydro-generators,
gas
turbine
generators
and
pumped-storage
generators.
It
supports
wall
surface
mounted
and
flush
mounted
in
a
control
panel.
The
RCS-985G
is
fully
compatible
with
IEC
61850
communication
with
an
additional
communication
unit.