Price | To be quoted |
MOQ | 1 |
Delivery Time | goods in stock |
Brand | kingpo |
Place of Origin | china |
Certification | iso9001 ce |
Model Number | IEC 62368-1-Annex R |
Packaging Details | safety carton pack or plywood box |
Payment Terms | T/T |
Supply Ability | 100 set/ month |
Input voltage | AC220V±10% 3KW | Place of Origin | china |
Packaging Details | safety carton pack or plywood box | Model Number | IEC 62368-1-Annex R |
Supply Ability | 100 set/ month | Certification | iso9001 ce |
Standards | IEC62368-1 | Discharge time | 5-20ms |
Brand Name | kingpo | Payment Terms | T/T |
Price | To be quoted | Delivery Time | goods in stock |
Output voltage | DC120-250V | Control mode | PC |
Minimum Order Quantity | 1 | Output current | ≥1500A |
Limited short-circuit test , IEC 62368-1-Annex R
R.3
Test
method
The
source
shall
be
applied
to
the
EUT
via
the
mains
cord
supplied
or
specified
by
the equipment
manufacturer.
Where
there
is
no
mains
cord
supplied
or
specified,
a
1
m
length
of 2,5
mm
2
or
12
AWG
shall
be
used.
For
DC
sources,
the
cable
shall
be
sized
for
the
maximum rated
current
of
the
equipment.
To
conduct
this
test
a
short-circuit
in
the
equipment
to
the
earth
connection
of
the
equipment shall
be
introduced.
The
point
at
which
this
is
done
is
depending
on
the
equipment.
After consideration
of
the
equipment
construction
and
circuit
diagrams,
the
short-circuit
shall
be introduced
between
the
phase
conductor,
at
the
point
nearest
to
the
input
(the
point
of
lowest impedance),
and
the
protective
bonding
path
under
consideration.
There
may
be
more
than one
point
at
which
this
short-circuit
may
be
applied
to
determine
the
worst
case.
The
protective
bonding
conductor
is
connected
to
a
source
capable
of
supplying
an
AC
or DC
current,
as
appropriate
to
the
EUT,
of
1
500
A
under
short-circuit
conditions,
and
using
a source
voltage
equal
to
the
rated
voltage
or
any
voltage
within
the
rated
voltage
range
of the
equipment.
In
cases
where
the
prospective
short-circuit
current
seen
by
the
equipment
is known,
then
the
source
used
for
test
shall
be
able
to
supply
that
current
under
short-circuit conditions.
The
manufacturer
shall
state
the
prospective
short-circuit
current
that
has
been used
in
the
evaluation
in
the
safety
instructions.
The
overcurrent
protective
device
protecting the
circuit
under
consideration
(in
accordance
with
Clause
R.2)
is
kept
in
series
with
the protective
bonding
conductor.
The
power
supply
cord,
if
provided
or
specified,
shall
remain connected
when
conducting
the
test.
The
limited
short-circuit
test
for
protective
bonding
conductors
in
a
potted
or
conformally coated
assembly
is
conducted
on
a
potted
or
coated
sample.
The
test
is
conducted
two
more
times
(for
a
total
of
three
times,
on
a
different
sample
unless the
manufacturer
agrees
to
conduct
the
test
on
the
same
sample).
The
test
is
continued
until the
overcurrent
protective
device
operates.
Parameters:
Discharge voltage range: dc120-250v (customizable)
Discharge limit current: ≥1500A (customizable)
Discharge time: 5-100ms adjustable
Control mode: PC
Power : AC220V± 10% 50Hz 3000W
External dimensions: 1060×788×1361mm
Equipment weight: 240Kg
Equipment structure:
Feature:
First charge the battery inside the device, discharge it to the set voltage, and then realize the instantaneous high current test. The discharge time and voltage can be set. After the discharge is completed, it will automatically charge for the next test. The discharge current is recorded during the test, and the system will automatically generate a current-time curve.
Function:
▪ automatic/manual features;
▪ discharge voltage and limit protection time can be set;
▪ waveform curve analysis function;
▪ with overpressure overcurrent protection function;
▪ operation interface (as shown below)