Price | Negotiation |
MOQ | 1 set |
Delivery Time | 20 work days |
Brand | YUYANG |
Place of Origin | China |
Certification | ASTM D 2863, ISO 4589-2, NES 714, GB2406 |
Model Number | YY710 |
Packaging Details | Plywood Box |
Payment Terms | T/T, L/C, Western Union |
Supply Ability | 2 sets per month |
Usage | ISO5659-1 and ISO5659-2 Test | Heating cone power | 2600W |
Place of Origin | China | Packaging Details | Plywood Box |
Product Name | smoke density chamber | Model Number | YY710 |
Supply Ability | 2 sets per month | radiation exposure | 10KW / m²-50KW / m² |
Certification | ASTM D 2863, ISO 4589-2, NES 714, GB2406 | Brand Name | YUYANG |
Payment Terms | T/T, L/C, Western Union | input temperature range | 0 ~ 1000℃ |
Price | Negotiation | Delivery Time | 20 work days |
Minimum Order Quantity | 1 set | Voltage | 220V |
light source | 6.5V | Power | 4KW |
4KW Plastic Smoke Density Tester with 6.5V Light Source, GB/T8323.2 Testing Equipment
Brief Introduction:
The
main
principle
of
smoke
density
measurement
is
that
in
a
particular
space,
the
cable
or
material
produces
smoke
under
specific
combustion
or
radiation
conditions,
and
the
light
beam
penetrating
through
the
smoke
will
produce
attenuation.
Measuring
the
light
transmittance
and
calculation
will
get
the
optical
density
and
smoke
density.
The
instrument
is
designed
and
developed
according
to
ISO5659
related
standards.
With
the
use
of
Conical
radiation
furnace,
the
heat
flux
in
the
chamber
can
be
as
high
as
50
kW
per
,
and
the
sample
can
be
positioned
horizontally
to
test
the
mass
loss
rate
of
the
sample.
This
also
complies
with
the
latest
IMO
test
terms.
Measure
the
amount
of
smoke
generated
when
the
sample
is
vertically
exposed
to
a
radioactive
heat
source
at
25
kW
/
m2
when
there
is
or
there
is
no
forward
flame
in
confined
space.
Using
the
standard
ISO
5659
conical
radiant
heating
furnace,
the
user
can
adjust
the
heating
conditions
from
10
kW
into
50
kW
or
70kW
Standards:
GB/T8323.2-2008:
Plastics
-
Smoke
generation
-
Part
2:
Determination
of
optical
density
by
a
single-chamber
test
ISO
5659-1:
Plastics
-
Smoke
generation
-
Part
2:
Determination
of
optical
density
by
a
single-chamber
test
ISO
5659-2:
Plastics-Smoke
generation-Part2:
Determination
of
optical
density
by
a
single-chamber
test
Feature:
1.
The
tester
consists
of
a
chamber,
a
sample
box,
a
radiant
cone,
an
igniter,
a
light
transmission
and
measuring
device
and
other
related
control
devices.
2.
Ergonomic
design
and
control
design;
chamber
with
a
fully
open
door
;
door
lock
designed
to
facilitate
one-time
closure
of
the
door;
optimize
the
operation
process.
3.
The
test
chamber
door
can
be
fully
opened
to
facilitate
loading
and
unloading
samples
and
cleaning
the
box;
4.
Front
door,
hinge
mounted,
with
window
and
non-transparent
light
shading
board
which
can
block
the
window,
to
prevent
light
from
entering
the
sealed
chamber.
5.
The
controller
is
located
on
the
side
of
the
chamber
for
easy
operation.
When
the
door
is
closed,
it
does
not
affect
the
controller
to
be
viewed.
6.
Safe
flameout
board,
easy
to
replace,
more
secure
operation.
7.
A
gas
measuring
port
is
available
for
testing
gas
toxicity.
8. The coating of the test chamber is easy to clean and resistant to chemical corrosion.
Combustion Apparatus:
1.
Heating
cone:
power
2600W,
input
temperature
range
of
0
~
1000℃,
stable
within
±
2℃
within
50
mins,
can
provide
10KW
/
m²-50KW
/
m²
of
radiation
exposure.
2.
The
use
of
mass
flow
controllers
and
differential
pressure
sensors
enhances
the
accuracy
of
the
manometer
and
enables
automatic
leak
testing.
3.
The
ignitor
is
equipped
with
automatic
ignition
device;
flame
length
30mm
±
5mm;
in
accordance
with
the
standard
provisions
of
blue
flame
with
yellow
on
the
top.
4.
Smoke
density
and
temperature
are
digital
displayed,
more
simple
view,
more
accurate
value
5.
Photoelectric
detection
components
include
photomultiplier
tubes,
amplifying
filters,
optical
shutters,
optical
filters,
neutral
optical
filters,
lenses,
optical
windows,
etc.
6.
The
light
source
is
6.5V
incandescent
lamp.
7.
An
optical
cartridge
is
installed
on
the
top
of
the
chamber.
the
light
source
is
receipted
by
the
side
window
type
photoelectric
multiplier.
Light
transmittance
accuracy
can
reach
0.001%
8.
Achromatic
lens
9.
Silicon
photovoltaic
cells
10.
High
gain
and
low
noise
amplifier
control
circuit
Smoke
Density
Measurement
System:
1.
Smoke
density
and
temperature
are
digital
displayed,
more
simple
view,
more
accurate
value
2.
Photoelectric
detection
components
include
photomultiplier
tubes,
amplifying
filters,
optical
shutters,
optical
filters,
neutral
optical
filters,
lenses,
optical
windows,
etc.
3.
The
light
source
is
6.5V
incandescent
lamp.
4.
An
optical
cartridge
is
installed
on
the
top
of
the
chamber.
the
light
source
is
receipted
by
the
side
window
type
photoelectric
multiplier.
Light
transmittance
accuracy
can
reach
0.001%
5.
Achromatic
lens
6.
Silicon
photovoltaic
cells
7.
High
gain
and
low
noise
amplifier
control
circuit
8.
Automatic
completion
of
the
test;
a
variety
of
signals
automatically
collected
9.
Branded
computer
Control
System:
1.
Automatic
completion
of
the
test;
a
variety
of
signals
automatically
collected
2.
Branded
computer
3.
The
printer
is
optional
4.
Voltage:
220V;
Power
4KW
5.
Propane
gas
customer-owned