KLD800 Series 80G Radar Level Gauge PTFE Antenna Size Small Blind Spot

Price Negotiable
MOQ 1PCS
Delivery Time 5-8 work days
Brand KACISE
Place of Origin CHINA
Certification CE
Model Number KLD801
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability 1000 Piece/Pieces per Week negotiable

Product Details

Product Specification

Place of Origin CHINA Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Measuring range 0.05m~10/20/30/60/100m Center frequency 123GHz/80GHz
Antenna size 32/34/76mm lens antenna Power supply Two-wire /DC24V
Model Number KLD801 Casing aluminum/plastic/stainless steel
Supply Ability 1000 Piece/Pieces per Week negotiable Certification CE
Brand Name KACISE Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram
Accuracy ±1/±5mm Antenna material PTFE
Price Negotiable Delivery Time 5-8 work days
Protection class IP67 Medium refer to detailed description
Process connection refer to detailed description Process temperature -40~220℃
Signal output two-wire /4...20mA/HART protocol Minimum Order Quantity 1PCS
Launch angle 3°/2° Process pressure -0.1~2.5 MPa

Product Description

KLD800 Series 80G Radar Level Gauge PTFE Antenna Size Small Blind Spot
Product Attributes
Attribute Value
Medium refer to detailed description
Measuring range 0.05m~10/20/30/60/100m
Process connection refer to detailed description
Process temperature -40~220℃
Process pressure -0.1~2.5 MPa
Antenna size 32/34/76mm lens antenna
Antenna material PTFE
Accuracy ±1/±5mm
Protection class IP67
Center frequency 123GHz/80GHz
Launch angle 3°/2°
Power supply Two-wire /DC24V
Casing aluminum/plastic/stainless steel
Signal output two-wire /4...20mA/HART protocol
Product Description

The KLD-80G series radar level gauge is an 80G ultra-high frequency, millimeter-wave radar with a measurement accuracy of up to ±2mm and a minimum blind zone of 0.05m. Lens antenna design, smaller beam angle, more suitable for complex working conditions such as small-diameter tanks and stirring coils in the tank.

With stronger penetrability and multiple measurement modes, various antennas can be selected according to different industries and mines to ensure that the radar can also measure stably and accurately under complex conditions such as high temperature, high pressure and high dust.

The high-frequency 80g radar level gauge has the advantages of low maintenance, high performance, high precision, high reliability, and long service life. Compared with contact instruments such as capacitors and weights, it has incomparable advantages.

Key Features
  • Millimeter wave radar, the measurement accuracy can reach up to ±2mm, and the minimum measurement blind zone is 0.05m.
  • The smaller antenna size satisfies the measurement of more working conditions.
  • A variety of lens antennas, smaller launch angles, more concentrated energy, stronger echo signals.
  • It has stronger penetration and can be used normally in the case of adhesion and condensation.
  • The dynamic signal range is larger, and the measurement of low dielectric constant media is more stable.
  • Multiple measurement modes, radar response in fast measurement mode.
Model Specifications
KLD801
KLD801 Radar Level Gauge

Medium: liquid, non-corrosive

Measuring range: 0.05m~10/20/30/60/100m

Process connection: G1½A / 1½NPT thread / flange ≥ DN40

Process temperature: -40~80℃

Process pressure: -0.1~0.3 MPa

Antenna size: 32mm lens antenna

Antenna material: PTFE

Accuracy: ±1mm

Protection class: IP67

Center frequency: 123GHz

Launch angle:

Power supply: Two-wire /DC24V

Casing: aluminum/plastic/stainless steel

Signal output: two-wire /4...20mA/HART protocol

KLD802
KLD802 Radar Level Gauge

Medium: non-corrosive liquid, slightly corrosive liquid

Measuring range: 0.1m~10/20/30/60/100m

Process connection: flange ≥ DN80

Process temperature: -40~110℃

Process pressure: -0.1~1.6MPa

Antenna size: 32mm lens antenna

Antenna material: PTFE

Accuracy: ±1mm (range below 35m) ±5mm (range between 35m and 100m)

Protection class: IP67

Center frequency: 80GHz

Launch angle:

Power supply: two-wire /DC24V

Casing: aluminum/stainless steel

Signal output: two-wire /4...20mA/HART protocol

KLD803
KLD803 Radar Level Gauge

Medium: strong corrosive liquid, steam, foam

Measuring range: 0.1m~10/20/30/60/100m

Process connection: flange ≥ DN50

Process temperature: -40~130℃

Process pressure: -0.1~2.5MPa

Antenna size: 34mm lens antenna

Antenna material: PTFE

Accuracy: ±1mm (range below 35m) ±5mm (range between 35m and 100m)

Protection class: IP67

Center frequency: 80GHz

Launch angle:

Power supply: two-wire /DC24V

Casing: aluminum/stainless steel

Signal output: two-wire /4...20mA/HART protocol

KLD804
KLD804 Radar Level Gauge

Medium: strong corrosive liquid, steam, foam

Measuring range: 0.1m~10/20/30/60/100m

Process connection: flange ≥ DN50

Process temperature: -40~130℃

Process pressure: -0.1~1.0MPa

Antenna size: 76mm lens antenna

Antenna material: PTFE

Accuracy: ±1mm

Protection class: IP67

Center frequency: 80GHz

Launch angle:

Power supply: two-wire /DC24V

Casing: aluminum/plastic/stainless steel

Signal output: two-wire /4...20mA/HART protocol

KLD805
KLD805 Radar Level Gauge

Medium: strong corrosive liquid, steam, foam, high temperature and high pressure

Measuring range: 0.1m~10/20/30/60/100m

Process connection: flange ≥ DN80

Process temperature: -40~200℃

Process pressure: -0.1~2.5MPa

Antenna size: 76mm lens antenna

Antenna material: PTFE/overall filling

Accuracy: ±1mm

Protection class: IP67

Center frequency: 80GHz

Launch angle:

Power supply: two-wire /DC24V

Casing: aluminum / plastic / stainless steel

Signal output: two-wire /4...20mA/HART protocol

KLD806
KLD806 Radar Level Gauge

Medium: solid, storage container, process container, strong dust application

Measuring range: 0.3m~10/20/30/60/100m

Process connection: flange ≥ DN100

Process temperature: -40~110℃

Process pressure: -0.1~0.3MPa

Antenna size: 76mm lens antenna (purge optional)

Antenna material: PTFE

Accuracy: ±5mm

Protection class: IP67

Center frequency: 80GHz

Launch angle:

Power supply: two-wire /DC24V

Casing: aluminum/plastic/stainless steel

Signal output: two-wire /4...20mA/HART protocol

Installation Connection Diagram

The maximum installation spool height H max depends on the installation spool diameter D and the size of the product launch angle. Too long installation connection will affect the radar performance.

KLD801/02
KLD801/02 Installation Diagram
KLD803/KLD804/KLD805A
KLD803/KLD804/KLD805A Installation Diagram
KLD806
KLD806 Installation Diagram
Power Supply
Type Description
(4~20) mA/HART(2 wire) The power supply and the output current signal share a two-core shielded cable. Please refer to the technical data for the specific supply voltage range.
(4~20) mA(4 wire/6 wire) The power supply needs to be powered separately, and a four-core shielded cable is used for the power supply and current signal (the current signal and the RS485 interface can be output at the same time, and a six-core shielded cable is required for simultaneous output).
RS485/Modbus The power supply needs to be powered separately, and a four-core shielded cable is used for power supply and digital signal. (The current signal and the RS485 interface can be output at the same time, and a six-core shielded cable is required for simultaneous output).
Connection Diagram
Connection Diagram
Safety Guide

Please observe the requirements of the local electrical installation regulations!

Follow local regulations for personnel health and safety. All operations on the electrical components of the instrument must be completed by professionals who have received formal training.

Please check the nameplate of the instrument to ensure that the product specification meets your requirements. Please ensure that the power supply voltage is consistent with the requirements on the nameplate of the instrument.

Grade of Protection

This instrument fully meets the requirements of protection class IP66/67, please ensure the waterproofness of the cable sealing head.

Protection Grade Diagram

How to ensure that the installation meets the requirements of IP67:

  • Make sure the sealing head is not damaged.
  • Make sure the cable is not damaged.
  • Please make sure that the cables used meet the requirements of the electrical connection regulations.
  • Before entering the electrical interface, bend the cable down to ensure that water will not flow into the housing.
  • Please tighten the cable gland.
  • Please plug the unused electrical interface with a blind plug.
Casing Dimension

Unit in mm:

Casing Dimension Diagram
Product Dimension

Unit in mm:

KLD801
KLD801 Dimension Diagram KLD801 Additional Dimension Diagram
KLD802
KLD802 Dimension Diagram
KLD803
KLD803 Dimension Diagram
KLD806
KLD806 Dimension Diagram
KLD804 & KLD805
KLD804 & KLD805 Dimension Diagram