The
KLSA-PN
Laser
Ranging
Sensor
For
Topographic
Mapping
Product
Attributes
Attribute
|
Value
|
Output
|
RS485/Simulation/PNP/NPN/Relay/UART
|
Measuring
range
|
20m
|
Measuring
frequency
|
50...100...250Hz
|
Fade
zone
|
0.2m
|
Work
laser
|
905nm,
Class
1
|
Working
temperature
|
-20~50℃
|
Product
Description
The
KLSA-PN
laser
ranging
sensor
is
a
precision
instrument
that
uses
laser
technology
to
achieve
non-contact
distance
measurement.
It
determines
the
distance,
position
or
displacement
of
the
target
object
by
emitting
laser
and
analyzing
the
reflected
signal.
Its
core
advantages
are
high
precision,
long
distance,
fast
response
and
anti-interference
ability.
Key
Features
-
Can
be
used
as
a
laser
distance
sensor
with
measurement
range
of
0.03
to
22
m
-
Background
suppression
of
22
m
-
4-digit
display
for
measured
values
-
RS485
signal
and
analog
4-20mA
signal
output
-
Distance
between
sensor
and
background
must
be
limited
to
≤22
m
for
accurate
measurements
Technical
Specifications
Performance
Parameters
Measurement
range
|
Maximum
measuring
distance:
22m
Under
strong
light
@100KLux
environment:
12m
Under
black
target
with
10%
reflectivity:
20m
|
Measurement
frequency
|
100HZ
(frequency
adjustable)
|
Repeat
accuracy
|
±8.0mm
@50~2000mm
±20.0mm
@2000~6000mm
±30.0mm
@6000~20000mm
|
Absolute
accuracy
|
±20.0mm@200~2000mm;
20~200mm
near
blind
area,
large
error
±30.0mm
@2000~6000mm
<1%
@6000~20000mm
|
Multi-target
detection
|
Double
peak
|
Temperature
compensation
|
Yes
|
Reflectivity
correction
|
Yes,
the
deviation
of
different
color
targets
is
less
than
5mm
|
Blind
area
|
0.03m
|
Light
Source
Working
laser
|
905nm,
Class
1
|
Field
of
view
FOV
|
<2°
|
Spot
size
|
Φ3.5cm@1m:
Φ11.5cm@5m
Φ23cm@10m;
Φ50cm@20m
|
Indicator
laser
|
650-660nm,
Class
2,
(IEC
60825-1:2014,
EN
60825-1:2014)
|
Working
Environment
Working
temperature
|
-20~50℃
|
Storage
temperature
|
-40~85℃
|
Enclosure
protection
level
|
IP65
|
Electrical
Parameters
Working
voltage
|
DC+9~35V
|
Working
current
|
107mA@12V
indicates
laser
working
103mA@12V
indicates
laser
off
|
Reverse
protection
|
Yes
|
Isolation
|
Yes
|
Laser
life
|
More
than
50000h
|
Output
Interface
Output
interface
|
Two-way
PNP
|
Two-way
NPN
|
RS485-Modbus
|
UART
|
Relay
Normally
open/closed
|
Normally
open/closed
|
4~20mA
|
Switch
output
maximum
current
load
|
100mA
|
Analog
output
maximum
load
|
250Ω
|
Display
Button
Nixie
tube
digits
|
4-bit
|
Button
function
|
Switch
value
adjustment;
laser
switch
indication;
analog
range
adjustment
|
Mechanical
Parameters
Weight
|
73g+3g
(glue
filling
error)
|
Casing
|
ABS
|
Dimensions
|
45*45*49.5mm
|
Accessories
Bolts
|
M4*55mm
2
|
Bracket
|
Optional
|
Electrical
connection
|
1*M8,
1
meter
long
cable
|
Safety
Instructions
-
Please
read
this
document
before
installing
the
device.
Make
sure
that
the
product
is
suitable
for
your
application
and
is
not
subject
to
any
restrictions.
-
Improper
use
or
use
of
the
device
for
purposes
other
than
those
specified
may
cause
the
device
to
malfunction
or
lead
to
unexpected
situations
during
use.
-
Only
qualified
personnel
authorized
by
the
device
operator
may
perform
installation,
electrical
connection,
settings,
operation
and
maintenance
of
the
device.
-
In
the
event
of
a
malfunction
in
the
device,
please
contact
the
manufacturer.
We
reject
any
liability
and
warranty
claims
arising
from
unauthorized
modifications
and/or
alterations
to
the
device.
Functions
Hysteresis
Function
Output
[Hno][Hnc].
Set
a
switch
point.
If
the
measured
value
changes
around
the
sensing
range,
the
hysteresis
function
can
keep
the
output
switch
state
stable.
Window
Function
Output
[Fno][Fnc].
Set
two
switch
points
for
near
and
far.
Use
the
window
function
to
monitor
the
defined
allowable
range.
Turn
Off
the
Laser
The
sensor
can
set
the
red
dot
to
indicate
the
laser
on
and
off
by
pressing
the
button.
It
does
not
affect
the
normal
distance
measurement.
Installation
Installation
Conditions
-
Install
the
device
so
that
the
object
to
be
measured
is
within
the
measuring
range
of
0.03...22
m.
-
The
sensor
has
a
fixed
accuracy
range
of
22
m.
Do
not
measure
objects
within
a
range
>
22
m.
-
The
customer
should
also
avoid
reflective
objects
in
the
direct
optical
path
of
the
sensor
within
a
range
>
22
m.
Otherwise,
the
measured
values
may
be
inaccurate.
Install
Accessories
Dimensions
Cable
Definition
NO.
|
Line
Color
|
KLSA-P/N
|
KLSA-DA
|
KLSA-T
|
1
|
Brown
|
VCC,
DC9-35V
|
VCC,
DC9~35V
|
VCC,
DC3.3V
|
2
|
Black
|
GND
|
GND,
analog
ground
|
Power
ground
|
3
|
Blue
|
OUT1
|
RS485
A
|
RX
|
4
|
White
|
OUT2
|
RS485
B
|
TX
|
5
|
Gray
|
None
|
Analog
output
|
|
Order
Model
Table
Range
|
Interface
|
Model
|
1m
|
PNP
|
KLSA-01P
|
2m
|
PNP
|
KLSA-02P
|
3m
|
PNP
|
KLSA-03P
|
4m
|
PNP
|
KLSA-04P
|
5m
|
PNP
|
KLSA-05P
|
5m
|
NPN
|
KLSA-05N
|
5m
|
RS485/4-20mA
|
KLSA-05DA
|
5m
|
Relay
|
KLSA-05R
|
10m
|
PNP
|
KLSA-10P
|
10m
|
NPN
|
KLSA-10N
|
10m
|
RS485/4-20mA
|
KLSA-10DA
|
10m
|
Relay
|
KLSA-10R
|
20m
|
PNP
|
KLSA-20P
|
20m
|
NPN
|
KLSA-20N
|
20m
|
RS485/4-20mA
|
KLSA-20DA
|
20m
|
Relay
|
KLSA-20R
|
20m
|
UART
TTL
|
KLSA-20T
|