80W
Vehicle
Emission
Gas
Analyzer
for
CO2
Measuring
Range
0.0-18.0
×10⁻²
and
Vehicle
Exhaust
Gas
Monitoring
Product
Description
The
KGD-WQ-515
Vehicle
Emission
Gas
Analyzer
is
used
to
monitor
the
exhaust
gas
emitted
by
vehicles.
Product
Introduction
KGD-WQ-515
Vehicle
Emission
Gas
Analyzer
is
used
to
monitor
vehicle
exhaust
emissions.
It
employs
non-dispersive
infrared
(NDIR)
gas
analysis
technology
and
ECD
long-life
electrochemical
sensing
technology
with
independent
intellectual
property
rights
to
measure
the
volume
concentrations
of
CO,
HC,
CO₂,
O₂,
and
NO
in
vehicle
exhaust
gases,
and
automatically
calculates
and
displays
the
air-fuel
ratio.
Product
Features
-
Portable
design
with
a
compact
size
-
Easy
to
operate,
offering
accurate
and
reliable
measurements
-
Multi-stage
filtration
system
design
for
enhanced
system
durability
-
Equipped
with
interfaces
for
oil
temperature
and
rotational
speed
Technical
Parameters
Gas
Type
|
Measuring
Range
|
Relative
Error
|
Absolute
Error
|
HC
|
(0
-
5000)×10⁻⁶,
(5001
-
9999)×10⁻⁶
|
±
5%,
±
10%
|
±
10×10⁻⁶
|
CO
|
(0.00
-
10.00)×10⁻²,
(10.01
-
14.00)×10⁻²
|
±
5%,
±
10%
|
±
0.03×10⁻²
|
CO₂
|
(0
-
18.0)×10⁻²
|
±
5%
|
±
0.5×10⁻²
|
NO
|
(0
-
4000)×10⁻⁶,
(4001
-
5000)×10⁻⁶
|
±
4%,
±
8%
|
±
25×10⁻⁶
|
O₂
|
(0
-
25.0)×10⁻²
|
±
5%
|
±
0.1×10⁻²
|
Note:
The
absolute
error
and
relative
error
listed
in
the
table,
meeting
one
of
the
requirements
is
sufficient.
Communication
|
RS-485/RS-232,
can
be
connected
to
Gasboard
series
smoke
analysis
equipment
|
Power
Supply
|
100-240VAC,
80W
|
Display
|
LCD
display
|