Price | Negotiable |
MOQ | 1PCS |
Delivery Time | 5-8 work days |
Brand | KACISE |
Place of Origin | CHINA |
Certification | CE |
Model Number | KGD-WQ-508 |
Packaging Details | each unit has individual box and all boxes are packed in standard packages or customers requests available |
Payment Terms | L/C,D/A,D/P,T/T,Western Union,MoneyGram |
Supply Ability | 1000 Piece/Pieces per Week negotiable |
Place of Origin | CHINA | Applicable Engine Range | Engines of any size, at any speed, and with exhaust pipes of various specifications |
Dilution Air Flow Control Accuracy | ≤ ±1% | Packaging Details | each unit has individual box and all boxes are packed in standard packages or customers requests available |
Dilution Exhaust Gas Flow Control Accuracy | ≤ ±1% | Model Number | KGD-WQ-508 |
Supply Ability | 1000 Piece/Pieces per Week negotiable | Certification | CE |
Brand Name | KACISE | Payment Terms | L/C,D/A,D/P,T/T,Western Union,MoneyGram |
Dilution Air Flow Control Range | 35 - 100 SLM | Delivery Time | 5-8 work days |
Dilution Exhaust Gas Flow Control Range | 35 - 100 SLM | Minimum Order Quantity | 1PCS |
Sampling Flow Measurement Accuracy | ≤ ±4% (Dilution ratio ≤ 15:1) |
Attribute | Value |
---|---|
Applicable Engine Range | Engines of any size, at any speed, and with exhaust pipes of various specifications |
Sampling Flow Measurement Accuracy | ≤ ±4% (Dilution ratio ≤ 15:1) |
Dilution Air Flow Control Range | 35 - 100 SLM |
Dilution Exhaust Gas Flow Control Range | 35 - 100 SLM |
Dilution Air Flow Control Accuracy | ≤ ±1% |
Dilution Exhaust Gas Flow Control Accuracy | ≤ ±1% |
KGD-WQ-508 Partial-flow Particulate Matter Sampling System
The KGD-WQ-508 Partial-flow Particulate Matter Sampling System is an automated device that mixes clean air with a small amount of raw exhaust gas sampling airflow to form diluted exhaust gas, and collects particulate matter in the diluted exhaust gas through a filter paper. This device uses a high-frequency flow control strategy to quickly and accurately control the sampling flow rate, making it change proportionally and synchronously with the total flow rate of the engine's raw exhaust gas. Thus, it can quantitatively analyze the PM concentration of exhaust gas particulate matter under the transient operating conditions of the engine.
Parameter | Details |
---|---|
Applicable Engine Range | Engines of any size, at any speed, and with exhaust pipes of various specifications |
Sampling Flow Measurement Accuracy | ≤ ±4% (Dilution ratio ≤ 15:1) |
Dilution Air Flow Control Range | 35 - 100 SLM |
Dilution Exhaust Gas Flow Control Range | 35 - 100 SLM |
Dilution Air Flow Control Accuracy | ≤ ±1% |
Dilution Exhaust Gas Flow Control Accuracy | ≤ ±1% |
Filter Paper Size | 47mm diameter or 70mm |
Pre-Heated Temperature of Filter Paper | 47 - 55°C |
Gas Flow Rate through Filter Paper | 35 - 100 cm/s |