Price | Negotiable |
MOQ | One Unit |
Delivery Time | 25-30 Work Days |
Brand | Ningbo Suntech Power |
Place of Origin | Ningbo,China |
Certification | ISO9001 |
Model Number | FKTF-280kVA/35kV;140kV |
Packaging Details | Export Standard Wooden Case With Fumigation Free |
Payment Terms | T/T |
Supply Ability | 10units/1months |
Max.capacity | OEM | Place of Origin | Ningbo,China |
Packaging Details | Export Standard Wooden Case With Fumigation Free | Test Principle | Variable Frequency Resonant Circuit |
Model Number | FKTF-280kVA/35kV;140kV | Supply Ability | 10units/1months |
High Light | 280kVA Series Resonant Test System, Frequency Modulation Type Resonant Test System, 35kV AC Resonant Test System | Certification | ISO9001 |
Test Item | AC Withstand Voltage Test Under 108KV | Power Supply | 380V±10% |
Rated Voltage | 35kV;140kV; | Brand Name | Ningbo Suntech Power |
Payment Terms | T/T | Price | Negotiable |
Delivery Time | 25-30 Work Days | Test Standard | IEC 60060-1:2010;IEC 62271-203:2011 For GIS, IEC 60840:2011 For XLPE Cable; |
Minimum Order Quantity | One Unit | Max. Voltage | OEM |
Test Frequency | 45-300Hz | Duty Cycle | 60 Mints |
Test Object | 35KV Cable , 10KV Cable,110KV Cable | Design Feature | Portable Type |
Frequency modulation type series resonance test device
1.Applicable
scope
of
device
1.
Meet
the
AC
withstand
voltage
test
of
10kV/300mm2
cable,
the
capacitance
per
unit
length
is
0.3755μF/km,
the
cable
length
is
2000m,
the
capacitance
of
the
tested
cable
is
0.75μF,
the
test
voltage
is
22kV,
and
the
test
time
is
5min;
2.
Meet
the
35kV/240mm2
cable
AC
withstand
voltage
test,
the
capacitance
per
unit
length
is
0.175μF/km,
the
cable
length
is
1000m,
the
capacitance
of
the
tested
cable
is
0.175μF,
the
test
voltage
is
52kV,
and
the
test
time
is
180min;
3.
Meet
the
AC
withstand
voltage
test
of
110kV/630mm2
cable,
the
capacitance
per
unit
length
is
0.1880μF/km,
the
cable
length
is
100m,
the
capacitance
of
the
tested
cable
is
0.188μF,
the
test
voltage
is
128kV,
and
the
test
time
is
60min;
2.
The
device
follows
the
standard
GB10229-88
"Reactor"
GB50150-2016
"Power
Equipment
Handover
Test
Regulations"
DL/T
596-1996
"Preventive
Test
Regulations
for
Power
Equipment"
GB1094.1-GB1094.6-96
"Enclosure
protection
grade"
GB2900
"Electrical
Terminology"
GB/T16927.1~2-1997
"High
Voltage
Test
Technology"
GB
191-2000
"Packaging,
Storage
and
Transportation
Graphical
Signs"
JB/T
9641-1999
"Test
Transformer"
IEC358(1990)
"Coupling
Capacitor
and
Capacitance
Voltage
Divider"
Q/WFK005-2005
"Test
Transformer"
Fanke
Company
Enterprise
Standard
Q/WFK008-2004
"Test
Reactor"
Fanke
Company
Enterprise
Standard
3.
Environmental
conditions
of
the
device
1.
Ambient
temperature:
-5℃-+45℃;
2.
Relative
humidity:
≤90﹪,
no
condensation;
3.
Altitude:
≤1000m.
4.Fourth,
the
main
technical
performance
requirements
of
the
device
1.
Rated
capacity:
280kVA;
2.
Rated
voltage:
35kV;
140kV;
3.
Rated
current:
2A;
4.
Power
supply:
380V±10%;
5.
Rated
capacity
of
variable
frequency
power
supply:
20kW;
6.
Working
frequency:
45-300Hz;
7.
Frequency
adjustment
fineness:
0.01Hz;
frequency
instability:
≤0.01%;
8.
Working
time:
180min
continuous
operation
is
allowed
under
rated
power;
9.
Temperature
rise:
after
rated
continuous
operation
for
180
minutes,
the
temperature
rise
of
each
part
of
the
device
is
≤65K;
10.
Output
waveform:
sine
wave,
waveform
distortion
rate
<1%;
11.
Quality
factor:
the
device
itself
Q>30
(when
f=40Hz);
12.
Protection:
with
overcurrent,
overvoltage
and
flashover
protection
(see
the
frequency
conversion
power
supply
section
for
details);
13.
Measurement
accuracy:
1.5
effective
value.