Product Specification

protection level IP66 Place of Origin China
Detection range 0~1000, 2000, 5000, 10000ppm, 30%Vol, 100%Vol optional Size 210*170*85mm (L*H*W)
Packaging Details paper box product type MIC300-CO
Model Number MIC300-CO Supply Ability 10000 set/month
Certification CE, Atex, RohS, ISO Weight 1.8(kg)
Brand Name Zetron Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Delivery Time in stock Minimum Order Quantity 1 piece
explosive grade Exd II CT6/DIP A20 TA, T6

Product Description

 

MIC300 Online Toxic and Harmful Gas Detector

OVERVIEW

 

● Explosion-proof, lightning-proof, anti-static, anti-reverse connection, anti-EMI, EMC electromagnetic interference, anti-pulse surge current impact;
● Comply with the latest national standards and obtain the CMC manufacturing license for measuring instruments, explosion-proof certification, and other qualifications;
3-wire 4-20mA standard signal output, 2 groups of relay switch, optional voltage output;
It also has standard bus RS485 output (RTU format) and optional integrated sound and light alarm;
● The concentration of the probe can be monitored in real-time through the computer and the data can be stored, analyzed, and printed on the computer;
● Automatic tracking of zero point to prevent drift. Support OEM or ODM customization service.
 
SPECIFICATION

 

Type
Fixed Gas Detector
Detection principle
Electrochemical, infrared, thermal conductivity, PID photoionization, and so on.
Depending on the type of gas, range, field environment and user demand,
Sensor can be customized
Sensor service life
Electrochemical principle: 2 ~ 3 years;
Infrared principle: 5 ~ 10 years;
Thermal conductivity: 5 years
Response time
T90≤30 seconds
Recovery time
≤30 seconds
Working environment
Temperature: -40 ℃ ~ + 70 ℃, humidity: ≤10 ~ 95% RH (regular)
Power supply reference
24V, 2.1A is possible to drive 40 units of toxic gas detector,
or 15 units of flammable, infrared gas detector.
Working method
Fixed type installation, online detection, diffusion type measurement
Protection level
IP65
Explosion-proof mark
ExdⅡCT6, certificate number: CNEx15.1283
Exterior dimensions
233×205×65mm (L×H×W)
Weight
1.0 Kg