Price | Negotiable |
MOQ | 1 piece |
Delivery Time | Negotiable |
Brand | Zetron |
Place of Origin | China |
Certification | CE |
Model Number | TH-3000 |
Packaging Details | paper carton |
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Place of Origin | China | Detection principle | PID light ion, other gas monitoring analysis optional electrochemical, infrared (NDIR), laser (TDLAS), Differential ultraviolet spectroscopy (DOAS) and other principles |
Packaging Details | paper carton | Dimensions | 1800mm*800mm*450mm |
Detection gas | VOCs, SO2, NOx, O2, CH4, CO, CO2, NH3, H2S and other gases | Model Number | TH-3000 |
Certification | CE | Sampling distance | standard 70 meters |
Operating voltage | 220VAC, 50Hz | Brand Name | Zetron |
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Product name | Online pollution source monitoring system |
Sampling humidity | 0~99%RH | Minimum Order Quantity | 1 piece |
Sampling temperature | -40 ℃~800℃(standard), optional: -40 ℃~1300℃, -40 ℃~2000℃ |
TH3000 VOCs Online Pollution Source Monitoring System
TH3000
VOCs
online
pollution
source
monitoring
system
is
mainly
used
in
a
variety
of
atmospheric
emission
pollution
sources
online
monitoring
analysis
and
plant
boundary
concentration
online
monitoring.
The
main
principles
are:
The
sampling
unit
collects
the
flue
gas
or
gas
to
be
measured
on
the
site,
and
the
pretreatment
unit
filters
the
dust,
reduces
temperature,
keeps
heat
by
electric
tracking,
and
double-effect
dehumidification
on
the
gas.
The
temperature
and
humidity
of
the
gas
to
be
measured
are
kept
in
a
fixed
range,
and
then
the
gas
detection
and
analysis
unit
is
used
to
detect
and
analyze
the
gas
concentration
to
be
measured
in
real
time
on
the
display
screen.
And
the
data
signal
can
be
transmitted
outward
to
the
PLC
or
computer
terminal,
or
can
be
transmitted
to
the
cloud
server
through
wireless
GPRS
or
network,
and
then
the
user
can
read
the
data
from
the
server,
which
can
realize
the
global
network
monitoring
and
analysis.
The
whole
process
is
automatic
processing
without
human
intervention.
Detection
parameters:
VOCs,
SO2,
NOx,
O2,
CH4,
CO,
CO2,
NH3,
H2S
and
other
gases,
but
also
can
detect
wind
speed,Wind
direction,
rainfall,
atmospheric
pressure,
pipeline
pressure,
temperature
and
humidity
and
other
meteorological
parameters,
can
also
be
equipped
with
pitot
tube
detection
of
flue
gas
temperature,Pressure,
flow
and
other
parameters
Measurement
range:
depending
on
the
actual
demand
of
the
test
site
Detection
principle:
PID
light
ion,
other
gas
monitoring
analysis
optional
electrochemical,
infrared
(NDIR),
laser
(TDLAS),Differential
ultraviolet
spectroscopy
(DOAS)
and
other
principles
Sampling
temperature:
-40
℃~800℃(standard),
optional:
-40
℃~1300℃,
-40
℃~2000℃
Sampling
humidity:
0~99%RH,
can
pretreat
wet
gas
Working
environment
of
main
machine:
-40
℃~70℃,
≤95%RH
Working
mode:
On-line
continuous
work,
pump-suction
sampling
(positive
pressure,
negative
pressure,
vacuum
environment
can
be)
Sampling
distance:
standard
70
meters
Sampling
flow:
adjustable,
4
L/min
(standard),
10
L/min,
optional
Operating
voltage:
220VAC,
50Hz
Output
signal:
4~20mA,
RS485,
multi-channel
passive
contact,
optional:
wireless
transmission,
network
transmission
Dimensions:
1800mm*800mm
wide
*450mm
thick
Protection
category:
IP66
outdoor
waterproof
type
Display
mode:
9
inch
touch
color
screen
display,
display
real-time
concentration,
real-time
curve,
average
value
and
other
parameters,
Linux
operating
system
Calculation
method:
the
flue
gas
is
converted
in
two
ways:
the
basic
oxygen
content
and
the
conversion
coefficient
Operating
system:
Linux
operating
system
or
Windows7
operating
system,
support
the
Windows
environment
microcomputer
database
and
communication
system
software,
with Equip
rich
man-machine
interface,
support
mouse,
U
disk,
keyboard,
touch
pad,
printer
and
other
equipment
Data
storage:
the
default
SD
card
storage,
storage
capacity
of
16G,
optional
U
disk
storage,
file
storage
according
to
the
establishment
of
daily
folders,
respectively
store
daily
test
data
Printing
mode:
optional
built-in
integrated
printer
or
wireless
Bluetooth
printer
for
printing
Alarm
mode:
Optional
with
type
acousto-optic
alarm
or
external
acousto-optic
alarm
*suitable
for
a
variety
of
temperature
and
humidity
or
dust
occasions
of
gas
detection
and
analysis,
*Automatic
back
blowing
system
is
optional,
*TH3000
built-in
dual-effect
compressor
water
cooling
dehumidification
system
and
1
meter
fine
dust
filter
sampling
head
(flange
installation),
sampling
distance
of
70
meters,
automatic
cooling,
automatic
drainage,
filter
tar.
The
stability
of
the
gas
can
be
controlled
at
4℃
or
5℃
to
meet
the
requirements
of
the
humidity
and
cleanliness
of
the
gas
for
the
analytical
instruments
of
various
principles.
TH3000VOCs
online
pollution
source
monitoring
system
is
suitable
for
a
variety
of
temperature
and
humidity
or
dust
occasions
of
gas
detection
and
analysis,
more
suitable
for
the
dryness
and
cleanliness
of
the
gas
requirements
of
the
analyzer.
Automatic
back
blowing
system
is
optional,
otherwise
the
dust
filter
needs
regular
manual
maintenance
and
cleaning.
The
whole
sampling
pipe
has
the
function
of
heat
preservation
and
electric
heat
tracking
constant
temperature
control,
which
is
conducive
to
removing
water
vapor
and
preventing
part
of
the
gas
from
dissolving
in
condensed
water.
The
accuracy
of
detection
and
analysis
can
be
prevented
from
freezing
in
the
freezing
environment
in
winter.
Q:
When
do
you
reply
to
messages?
A:
We
will
reply
you
for
your
inquiry
in
24
hours.
Q:
When
do
you
send
the
products?
And
how
do
you
send
it
?
A:
For
the
small
order,
we
will
send
out
the
goods
with
5
days,If
have
stock
,we
will
send
immediately.
We
send
them
by
ups,
fedex,
tnt
or
dhl.
For
big
order,
normal
is
20
days
will
finish.
Q:Do
you
accept
OEM
or
revised
logo,
color,
model,size?
A:Yes,
we
accept
OEM
for
the
qualify
buyer.
We
can
make
the
products
according
to
customer
personal
requirement.
Q:
How
about
the
quality
of
the
managements
?
A:
We
have
a
complete
quality
control
system
,
all
of
our
products
will
be
fully
pre-inspection
by
QC
departments
before
,shipping
to
you
.
We
have
the
certification
of
ISO,CE
we
could
send
the
certification
test
of
our
company
to
you.
Q:
How
about
your
after-sale
service?
A:
After
sending,
we
will
track
the
products
for
you
,
until
you
get
the
products.
When
you
got
the
goods,
test
them,
and
give
me
a
feedback.
If
you
have
any
questions
about
the
problem,
contact
with
us,
we
will
offer
the
solve
way
for
you.