China DS4-H2S-100 Electrochemistry Gas Sensor Standard Industrial Size For Easy Installation And Integration for sale
China DS4-H2S-100 Electrochemistry Gas Sensor Standard Industrial Size For Easy Installation And Integration for sale
  1. China DS4-H2S-100 Electrochemistry Gas Sensor Standard Industrial Size For Easy Installation And Integration for sale

DS4-H2S-100 Electrochemistry Gas Sensor Standard Industrial Size For Easy Installation And Integration

Price Negotiable
MOQ 1
Delivery Time 3-5 work days
Brand EC
Place of Origin Germany
Model Number DS4-H2S-100
Packaging Details Standard packaging
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 5000pcs

Product Details

Product Specification

Place of Origin Germany Packaging Details Standard packaging
Operating Temperature Range -40°C to +55°C Model Number DS4-H2S-100
Supply Ability 5000pcs Weight <6g
Brand Name EC Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Sensitivity 90 ± 20 nA/ppm Price Negotiable
Delivery Time 3-5 work days Minimum Order Quantity 1
Maximum Overload 200 ppm Measurement Range 0–100 ppm
Resolution 0.1 ppm

Product Description

 

                                               DS4-H2S-100 Electrochemistry Gas Sensor

 

Detection Principle:

 

Utilizes solid polymer electrochemical sensing technology based on the principle of electrochemical catalytic reaction. The sensor consists of three catalytic electrodes, a solid electrolyte, and gas diffusion holes. Gas reaches the working electrode through the diffusion holes, where electrochemical oxidation or reduction reactions occur on the porous micro-surface of the electrode. The solid electrolyte conducts electron transfer, outputting a current signal proportional to the gas concentration.

 

Features:

  • Standard industrial size for easy installation and integration.
  • No preheating required, ready for immediate use.
  • Low-power sleep mode for battery-powered and power-sensitive applications.
  • Factory-precalibrated for precision; no user calibration needed.
  • User-definable encryption codes to prevent misinsertion of other sensor types.
  • Self-identification capability for system integration.
  • Easy maintenance, reducing operational and maintenance costs.

Performance Parameters:

  • Measurement Range: 0–100 ppm
  • Resolution: 0.1 ppm
  • Maximum Overload: 200 ppm
  • Sensitivity: 90 ± 20 nA/ppm
  • Response Time: T50 < 10 seconds, T90 < 30 seconds

Physical Parameters:

  • Dimensions: 20mm (diameter) × 16.6mm (excluding pins)
  • Weight: <6g

Environmental Parameters:

  • Operating Temperature Range: -40°C to +55°C
  • Operating Humidity Range: Typically 15–90%RH, non-condensing

Warranty:

1 year. Refer to product documentation for specific terms and conditions.

 

Measurement Range 0–100 ppm
Resolution 0.1 ppm
Maximum Overload 200 ppm
Sensitivity 90 ± 20 nA/ppm
Response Time T50 < 10s, T90 < 30s
Linearity ±2% F.S.
Long-Term Drift <1%/month