China 7NH3-500S Ammonia Gas Sensor For Measuring Concentration OfAmmonia Gas for sale
China 7NH3-500S Ammonia Gas Sensor For Measuring Concentration OfAmmonia Gas for sale
  1. China 7NH3-500S Ammonia Gas Sensor For Measuring Concentration OfAmmonia Gas for sale
  2. China 7NH3-500S Ammonia Gas Sensor For Measuring Concentration OfAmmonia Gas for sale

7NH3-500S Ammonia Gas Sensor For Measuring Concentration OfAmmonia Gas

Price Negotiable
MOQ 1PCS
Delivery Time 5-8 work days
Place of Origin CN
Model Number 7NH3-500S
Packaging Details Standard packaging
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 5000PCS

Product Details

Product Specification

Nominal Range 0 ~ 500 ppm Place of Origin CN
Packaging Details Standard packaging Sensitivity (20℃) 0.035 ± 0.015 μA/ppm
Model Number 7NH3-500S Supply Ability 5000PCS
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram Zero Signal (20℃) < ± 0.2 μA
Baseline Shift (-40℃ ~ 50℃) < 5 ppm Price Negotiable
Delivery Time 5-8 work days Minimum Order Quantity 1PCS
Maximum Overload 1000 ppm Response Time (T90) ≤ 55 s

Product Description

 

                             7NH3-500S Ammonia Gas Sensor For Measuring Concentration OfAmmonia Gas

 

  • Product Uses:

The 7NH3 - 500S gas sensor is mainly used for measuring the concentration of ammonia gas. It is designed for specific instruments to ensure personal safety, and can be applied to occasions where ammonia concentration needs to be monitored, such as ammonia - containing industrial production processes, livestock and poultry breeding places with ammonia emissions, and environments using ammonia - based cleaning products.

  • Product Features:
    • Wide Measuring Range: With a nominal range of 0 - 500 ppm, it can meet the measurement requirements of ammonia concentration in most common scenarios, and can also withstand a maximum overload of 1,000 ppm.
    • High Sensitivity: The sensitivity at 20℃ is 0.035 ± 0.015 μA/ppm, which can detect trace amounts of ammonia gas, helping to discover ammonia leakage or concentration changes in time.
    • Fast Response: The response time (T90) is ≤ 55 s, which can quickly respond to the change of ammonia concentration, providing timely data support for real - time monitoring.
    • Good Stability: The zero signal at 20℃ is < ± 0.2 μA, and the baseline shift in the temperature range of - 40℃ - 50℃ is < 5 ppm. The long - term output drift is < 2% signal/month, which can maintain relatively stable performance in different environments.
    • Simple Installation: It can be used as a pin - to - pin replacement for standard 7 - series electrochemical ammonia sensors, which is convenient for equipment upgrading and maintenance. And it has no special requirements for installation orientation, with a housing made of ABS material, weighing about 8 g, which is lightweight and easy to install.
    • Intrinsic Safety: It has intrinsic safety characteristics, with a maximum current of < 0.2 mA at 1,000 ppm NH3, a maximum open - circuit voltage of 1.3 V, and a maximum short - circuit current of < 1.0 A, which can be used safely in some dangerous environments.
    • Good Environmental Adaptability: It can work normally in the temperature range of - 40℃ - 50℃, the pressure range of 1 ± 0.1 atm, and the humidity range of 15% - 90%RH (non - condensing), and has a certain adaptability to different environmental conditions.

 

 

Nominal Range 0 ~ 500 ppm
Maximum Overload 1,000 ppm
Sensitivity (20℃) 0.035 ± 0.015 μA/ppm
Response Time (T90) ≤ 55 s
Zero Signal (20℃) < ± 0.2 μA
Baseline Shift (-40℃ ~ 50℃) < 3 ppm
Resolution 1 ppm
Bias Voltage 0 mV
Temperature Range -40℃ ~ 50℃
Pressure Range 1 ± 0.1 atm
Humidity Range 15% ~ 90%RH (Non - condensing)
Long - term Output Drift < 2% signal/month
Recommended Storage Temperature 10℃ ~ 30℃
Expected Operating Life 2 years (in clean air)
Storage Life 6 months (in original packaging)
Warranty 12 months
Max. Current at 1,000 ppm NH3 < 0.2 mA
Max. Open - circuit Voltage 1.3 V
Max. Short - circuit Current < 1.0 A
Housing Material ABS
Weight 8 g