YJJ NE4-NO2 NE-NO2 Electrochemical Gas Sensors Are Used In Underground Garage Alarm Systems

Price Negotiable
MOQ 1
Delivery Time 5 to 8 working days
Brand YJJ
Place of Origin Japan
Model Number NE4-NO2 NE-NO2
Packaging Details Palletized
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 1500

Product Details

Product Specification

Operating temperature range -20 - +50℃ Place of Origin Japan
Packaging Details Palletized concentration range 0.0 - 20 ppm
Model Number NE4-NO2 NE-NO2 Supply Ability 1500
Brand Name YJJ Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Repeatability within 2% Response time 25 seconds
Price Negotiable Delivery Time 5 to 8 working days
Output voltage 600 + 150 nA /ppm Detection limit 0.1PPM
Minimum Order Quantity 1

Product Description

Product Description:

YJJ NE4-NO2 NE-NO2 Electrochemical Gas Sensors Are Used In Underground Garage Alarm Systems

 

Features:

NE4-N02 is an electrochemical nitrogen dioxide gas sensor developed for use in underground parking garages. Since the detected gas is an oxidizing gas, the output signal is different from that of reducing gases. It is a reverse signal, but the linearity of the signal is very good. Additionally, among the nitrogen oxide series, only nitrogen dioxide and dinitrogen tetroxide have the ability to be detected. Not all nitrogen oxides can be detected. Please note this. Characteristics

Item characteristic determination concentration range: 0.0 - 20 ppm

Output voltage: 600 + 150 nA /ppm (signal and reducing gas in opposite directions)

Repeatability: within 2%

Detection limit: 0.1 ppm

Response time: 25 seconds or less for 90% response

Zero point temperature characteristic: within 0.2 ppm (-20 - +50℃)

Operating temperature range: -20 - +50℃

 

Specifications:

Measured volume 0.1 liters (L)
Single response time < 1 second (s)
Total response time < 10 seconds (s)
DC supply voltage 5.0 Min