Price | 280 USD |
MOQ | 1 |
Delivery Time | In Stock |
Brand | ABB |
Place of Origin | USA / FI etc |
Certification | CE |
Model Number | DI890 |
Packaging Details | New Original Box |
Payment Terms | T/T / Paypal |
Supply Ability | 50 |
Article number | 3BSC690073R1 | Place of Origin | USA / FI etc |
Packaging Details | New Original Box | Product Name | Input Module |
Signal specification | NAMUR input level | Model Number | DI890 |
Supply Ability | 50 | Certification | CE |
Brand Name | ABB | Payment Terms | T/T / Paypal |
Signal Type | Proximity sensor (NAMUR) or Voltage free contact | Type | Analog Input |
Model No. | DI890 | Price | 280 USD |
Delivery Time | In Stock | Minimum Order Quantity | 1 |
Mechanics | S800 | Number of channels | 8 channels |
NEW
Original
ABB
Module
3BSC690073R1
S800
I/O
Digital
Input
Module
DI890
PR:D
Description
of
DI890:
The
DI890
Digital
Input
Module
has
8
channels.
The
module
includes
Intrinsic
Safety
protection
components
on
each
channel
for
connection
to
process
equipment
in
hazardous
areas
without
the
need
for
additional
external
devices.
Each
channel
is
galvanically
isolated
from
the
power
supply,
ground,
and
each
other.
Intrinsically
safe
Proximity
sensors
or
volt-free
contacts
can
be
powered
and
monitored
by
any
channel.
The
Proximity
sensor
should
conform
to
the
NAMUR
standard
and
line
faults
can
be
detected
without
any
additional
external
components.
For
line
faults
to
be
detected
when
using
volt-free
contacts,
external
resistors
should
be
connected
in
series
and
in
parallel
to
enable
the
state
of
the
field
circuit
to
be
sensed
by
the
input
channel.
All
eight
channels
are
galvanic
isolated
from
the
ModuleBus
and
power
supply
individually.
Power
to
the
input
stages
is
converted
from
the
24
V
on
the
power
supply
connections.
Three
LEDs
indicate
module
status
Fault
(Red),
Run
(Green)
and
Warning
(Yellow).
TU890
and
TU891
Compact
MTU
can
be
used
with
this
module
and
it
enables
two
wire
connection
to
the
process
devices
without
additional
terminals.
TU890
for
Ex
applications
and
TU891
for
non
Ex
applications.
General
Information
Type | Digital Input |
Signal specification | NAMUR input level |
Article number | 3BSC690073R1 |
Number of channels | 8 |
Signal type | Proximity sensor (NAMUR) or Voltage free contact |
HART | No |
SOE | No |
Redundancy | No |
High integrity | No |
Intrinsic safety | Yes |
Mechanics | S800 |
I/O
Modules
AI801 | AI810 | AI815 | AI820 | AI825 |
AI830A | AI835A | AI843 | AI845 | AI880A |
AI890 | AI893 | AI895 | AO801 | AO810V2 |
AO815 | AO820 | AO845A | AO890 | AO895 |
DI801 | DI802 | DI803 | DI810 | DI811 |
DI814 | DI818 | DI820 | DI821 | DI825 |
DI828 | DI830 | DI831 | DI840 | DI880 |
DI890 | DO801 | DO802 | DO810 | DO814 |
DO815 | DO818 | DO820 | DO821 | DO828 |
DO840 | DO880 | DO890 | DP820 | DP840 |
Detailed
data
Isolation | Individually isolated, channel-to-channel and to circuit common ground |
Filter times (digital, selectable) | 2, 4, 8, 16 ms; analog filter 1 ms |
Current limiting | Built in current limited sensor power |
Rated insulation voltage | 50 V |
Dielectric test voltage | 500 V a.c. |
Power dissipation | 1.4 W |
Current consumption +5 V Modulebus | Typ. 120 mA, Max. <150 mA |
Current consumption +24 V external | Typ. 50 mA, Max. <70 mA |
Diagnostics
Front LED’s | F(ault), R(un), W(arning), Channel 1-8 status and F(ault) |
Supervision |
Internal
process
supply Loop supervision |
Environment
and
certification
CE mark | Yes |
Electrical safety | IEC 61131-2, FM |
Hazardous Location | C1 Div 2 cULus, C1 Zone 2 cULus, ATEX Zone 2 |
Marine certification | ABS, BV, DNV-GL, LR, RS, CCS |
Protection rating | IP20 according to IEC 60529 |
Corrosive atmosphere ISA-S71.04 | G3 |
Climatic operating conditions | 0 to +55 °C (Storage -40 to +70 °C), RH=5 to 95 % no condensation, IEC/EN 61131-2 |
Pollution degree | Degree 2, IEC 60664-1 |
Mechanical operating conditions | IEC/EN 61131-2 |
EMC | EN 61000-6-4, EN 61000-6-2 |
Overvoltage categories | IEC/EN 60664-1, EN 50178 |
Equipment class | Class I according to IEC 61140; (earth protected) |
Max ambient temperature | 55 °C (131 °F), for vertical mounting in compact MTU 40 °C (104 °F) |
RoHS compliance | EN 50581:2012 |
WEEE compliance | DIRECTIVE/2012/19/EU |
Compability
Use with MTU | TU890, TU891 |
Keying code | AA |
Dimensions
Height | 119 mm (4.7”) |
Width | 45 mm (1.77”) |
Depth | 102 mm (4.01”), 111 mm (4.37”) including connector |
Weight | 0.2 kg (0.44 lbs.) |
Some
ABB
items
sold
by
WTL:
WTL
is
not
liable
for
any
personal
injury
or
property
damage
resulting
from
the
use
of
this
equipment.
It
is
buyer's
responsibility
as
to
the
safe
handling
&
operation
of
this
equipment
and
to
verify
equipment
is
compliance
to
their
machinery.
Our
Brands:
【Honeywell】 | Module DCS/PLC/Transmitter |
【Emerson/Delta V】 | Module/ CT Motor & Drives |
【ABB】 | I/O Module |
【AB】 | Module&Touch Screen |
【Rosemount】 | Transmitter |
【Yokogawa】 | Transmitter |
【Yaskawa】 | Servo Drive&Servo Motor |
【GE/Fanuc】 | IC69 Series PLC |
【Mitsubishi】 | Servo Drive&Servo Motor |
(Modicon,SMC,SICK,NORGREN,Siemens,Ebmpapst
etc.)